What should the continuous bright annealing furnace do when it stops
Aug. 31, 2020
What should the continuous bright annealing furnace do when it stops
1. Cut off the power supply of each heating zone, power off and cool down (100C/time). The temperature in each zone drops evenly.
2. When the furnace temperature drops to 800°C, replace the ammonia decomposition gas with nitrogen. After the fire of the front exhaust pipe goes out, continue
Purge the furnace hall with a small flow of nitrogen to 600°C and stop the nitrogen filling.
3. Stop the fan when the furnace temperature drops to 300°C.
4. When the furnace temperature drops to 200°C, the water stops.
5. After the annealing furnace is finished, there should be a lead belt in the furnace, ready to be used next time.
4. In case of a power failure, the power on can be resolved within 5 minutes. The furnace can be filled with a small amount of nitrogen, otherwise the furnace shutdown safety regulations shall be followed. If the ammonia decomposition gas is broken, the nitrogen gas at a flow rate of 12m3/h is immediately transported into the furnace. Ensure the normal pressure of the atmosphere in the furnace. And shut down the furnace.